Supreme Navy I equivalent
PCM40 is a hard PZT, low loss material for high power applications and an equivalent of Navy I materials. The high coupling factor and low dielectric and mechanical losses (tgδ, Qm) combined with high piezoelectric charge constant (d33) make the material ultimate for high power ultrasonic applications.
Higher piezoelectric charge coefficient
PCM40 provides a higher coupling factor and higher piezoelectric charge coefficient than competitive materials.
PCM40 can be exposed to high repetitive quasi-static and dynamic loads and is suitable for both constant and repetitive conditions in sonar, ultrasonic cleaning, and other high power applications
PCM40 may advantageously be used in these applications:
Medical transducers
Hydrophones
Level sensors
Dental cleaners
High power underwater transducers
| |
Symbol & unit |
PCM40 |
| DIELECTRIC PROPERTIES |
| Relative Dielectric Constant |
εT33 / ε0 |
1250 |
| Dielectric Loss Factor |
tgδ [10-4] |
25 |
| Dielectric Loss Factor at 400V/m |
tgδ [10-4] |
140 |
| ELECTROMECHANICAL PROPERTIES |
| Electromech. Coupling Factors |
kp |
0.61 |
| |
k31 |
0.34 |
| | | | | |