Test procedures
Multilayer actuators are tested during manufacturing and in final inspection before shipment. The tests and requirements shown in the table below are performed as standard. Additional tests and requirements can be agreed upon in cooperation with the customer.
|
Test
|
Procedure
|
Sampling
|
Requirements
|
|
Mechanical dimensions
|
Dimensions are measured with micrometer screw or calliper gauge depending on the size
|
|
Depends on dimensions and the product type. In most cases ±0,1 mm or ±2%, whichever is the largest.
|
|
Displacement
|
Displacement at maximum recommended voltage measured with LVDT
|
AQL 0.65
|
Depends on dimensions and product type. In most cases displacement within ±15% of specified value.
|
|
Capacitance
|
1kHz; 1,0Vrms
|
100%
|
Depends on dimensions and product type. In most cases capacitance within ±15% of specified value.
|
|
Dielectric loss factor
|
1kHz; 1,0Vrms
|
100%
|
Depends on dimensions and product type. In most cases dielectric loss within ±15% of specified value.
|
|
|
|
|
|
More information
|
|
|
Did you find what you were looking for? If not, try our custom products.



|
| |
|